PDS_VERSION_ID = PDS3 RECORD_TYPE = FIXED_LENGTH RECORD_BYTES = 84 FILE_RECORDS = 29 ^TABLE = "FILTER12.TAB" OBJECT = TABLE INTERCHANGE_FORMAT = ASCII ROWS = 29 ROW_BYTES = 84 COLUMNS = 12 SPACECRAFT_NAME = VIKING_LANDER_1 INSTRUMENT_NAME = CAMERA_2 DESCRIPTION = "This table contains data on the filter spectral responsivities for camera 1 on Viking Lander 1. The data are taken from Huck et al., Radiometric Performance of the Viking Mars Lander Cameras, NASA TM X-72692, 1975." OBJECT = COLUMN NAME = WAVELENGTH DATA_TYPE = ASCII_REAL START_BYTE = 1 BYTES = 5 FORMAT = "F5.3" UNIT = MICROMETERS DESCRIPTION = "The center wavelength of the interval over which the data were sampled. Data in this file were sampled every 0.025 micrometers between 0.4 and 1.1 micrometers." END_OBJECT = COLUMN OBJECT = COLUMN NAME = BB1_RESPONSIVITY DATA_TYPE = ASCII_REAL START_BYTE = 7 BYTES = 6 FORMAT = "F6.3" UNIT = "A/W" DESCRIPTION = "The responsivity function for the BB1 photodiode." END_OBJECT = COLUMN OBJECT = COLUMN NAME = BB2_RESPONSIVITY DATA_TYPE = ASCII_REAL START_BYTE = 14 BYTES = 6 FORMAT = "F6.3" UNIT = "A/W" DESCRIPTION = "The responsivity function for the BB2 photodiode." END_OBJECT = COLUMN OBJECT = COLUMN NAME = BB3_RESPONSIVITY DATA_TYPE = ASCII_REAL START_BYTE = 21 BYTES = 6 FORMAT = "F6.3" UNIT = "A/W" DESCRIPTION = "The responsivity function for the BB3 photodiode." END_OBJECT = COLUMN OBJECT = COLUMN NAME = BB4_RESPONSIVITY DATA_TYPE = ASCII_REAL START_BYTE = 28 BYTES = 6 FORMAT = "F6.3" UNIT = "A/W" DESCRIPTION = "The responsivity function for the BB4 photodiode." END_OBJECT = COLUMN OBJECT = COLUMN NAME = BLUE_RESPONSIVITY DATA_TYPE = ASCII_REAL START_BYTE = 35 BYTES = 6 FORMAT = "F6.3" UNIT = "A/W" DESCRIPTION = "The responsivity function for the BLUE photodiode." END_OBJECT = COLUMN OBJECT = COLUMN NAME = GREEN_RESPONSIVITY DATA_TYPE = ASCII_REAL START_BYTE = 42 BYTES = 6 FORMAT = "F6.3" UNIT = "A/W" DESCRIPTION = "The responsivity function for the GREEN photodiode." END_OBJECT = COLUMN OBJECT = COLUMN NAME = RED_RESPONSIVITY DATA_TYPE = ASCII_REAL START_BYTE = 49 BYTES = 6 FORMAT = "F6.3" UNIT = "A/W" DESCRIPTION = "The responsivity function for the RED photodiode." END_OBJECT = COLUMN OBJECT = COLUMN NAME = IR1_RESPONSIVITY DATA_TYPE = ASCII_REAL START_BYTE = 56 BYTES = 6 FORMAT = "F6.3" UNIT = "A/W" DESCRIPTION = "The responsivity function for the IR1 photodiode." END_OBJECT = COLUMN OBJECT = COLUMN NAME = IR2_RESPONSIVITY DATA_TYPE = ASCII_REAL START_BYTE = 63 BYTES = 6 FORMAT = "F6.3" UNIT = "A/W" DESCRIPTION = "The responsivity function for the IR2 photodiode." END_OBJECT = COLUMN OBJECT = COLUMN NAME = IR3_RESPONSIVITY DATA_TYPE = ASCII_REAL START_BYTE = 70 BYTES = 6 FORMAT = "F6.3" UNIT = "A/W" DESCRIPTION = "The responsivity function for the IR3 photodiode." END_OBJECT = COLUMN OBJECT = COLUMN NAME = SURVEY_RESPONSIVITY DATA_TYPE = ASCII_REAL START_BYTE = 77 BYTES = 6 FORMAT = "F6.3" UNIT = "A/W" DESCRIPTION = "The responsivity function for the SURVEY photodiode." END_OBJECT = COLUMN END_OBJECT = TABLE END